Conditions of Conformance
Programming Module

When this product is used in applications governed by the requirements of the EEC, the following restric- tions and conditions apply:

1. For European applications, requiring compliance to the Low Voltage Directive, 73/ 23/ EEC, this power supply is considered a component product, designed for “built in” applications. Because it is incomplete in construction, the end product enclosure must provide for compliance to any remaining electrical safety requirements and act as a fire enclosure. (EN61010- 1 Cl. 6, Cl. 7, Cl. 8, Cl. 9 and EN61010-1 annex F)

2. This power supply is designed for stationary installation either within an equipment rack or a KEPCO Rack Adapter RA 55 or CA 400.

3. This power supply is considered a Class 1 (earthed) product, and as such depends upon proper connection to protective earth for safety from electric shock. (EN61010- 1 Cl. 6.5.4)

4. This power supply is intended for use as part of equipment meant for test, measurement and laboratory use, and is designed to operate from single phase, three wire power systems. This equipment must be installed in a specifically designed KEPCO rack adapter and within a suitably wired equipment rack, utilizing a three wire (grounded) mains connection. See wiring section of this manual for complete electrical wiring instructions. (EN61010- 1 Cl. 6. 5.4 and Cl. 6.10.1)

5. This power supply has secondary output circuits that are considered SELV.

6. This power supply employs a supplementary circuit protector in the form of a fuse mounted within its enclosure. The fuse protects the power supply itself from damage in the event of a fault condition. For complete circuit protection of the end product, as well as the building wiring, it is required that a primary circuit protection device be fitted to the branch circuit wiring. (EN61010- 1 Cl. 9.6. 2)

7. Hazardous voltages are present within this power supply during normal operation. All operator adjustments to the product are made via externally accessible switches, controls and signal lines as specified within the product operating instructions. There are no user or operator serviceable parts within the product enclosure. Refer all servicing to qualified and trained Kepco service technicians.

TOP NEXT

Applicability of BIT 4882 and BIT 4882-F Cards to Specific BOP Models Applicability of BIT 4882  and BIT 4882-F Cards to Specific BOP Models