BOP 1 KILOWATT MODEL TABLE
|
|
MODEL
|
d-c OUTPUT RANGE
|
CLOSED LOOP GAIN
|
OUTPUT IMPEDANCE
|
VOLTAGE
(V d-c)
|
CURRENT
(A d-c)
|
VOLTAGE CHANNEL
GV (V/V)
|
CURRENT CHANNEL
GI (A/V)
|
VOLTAGE MODE
|
CURRENT MODE
|
SERIES R
(mΩ)
|
SERIES L (µH)
|
SHUNT R (Ω)
|
SHUNT C (µF)
|
|
1000 WATT
|
| BOP 6-125MG |
0 to ±6 |
0 to ±125 |
0.6 |
12.5 |
0.05 |
1.5 |
24 |
1150 |
| BOP 10-75MG |
0 to ±10 |
0 to ±75 |
1.0 |
7.5 |
0.13 |
2.0 |
67 |
976 |
| BOP 20-50MG |
0 to ±20 |
0 to ±50 |
2.0 |
5.0 |
0.40 |
8.3 |
200 |
371 |
| BOP 25-40MG |
0 to ±25 |
0 to ±40 |
2.5 |
4.0 |
0.63 |
15.8 |
313 |
165 |
| BOP 36-28MG |
0 to ±36 |
0 to ±28 |
3.6 |
2.8 |
1.30 |
25 |
640 |
103 |
| BOP 50-20MG |
0 to ±50 |
0 to ±20 |
5.0 |
2.0 |
2.50 |
50 |
1250 |
55 |
| BOP 72-14MG |
0 to ±72 |
0 to ±14 |
7.2 |
1.4 |
5.14 |
104 |
2570 |
33 |
| BOP 100-10MG |
0 to ±100 |
0 to ±10 |
10.0 |
1.0 |
10.0 |
163 |
5000 |
16 |
|
NOTE: When connecting active loads, the steady-state voltage of the active load must not exceed the maximum voltage rating of the BOP. Otherwise the overvoltage protection will shut down the power supply.
|
|
BOP 1 KILOWATT SERIES GL MODEL TABLE
|
|
MODEL
|
d-c OUTPUT RANGE
|
CLOSED LOOP GAIN
|
RIPPLE AND NOISE
|
EO MAX.
(V d-c)
|
IO MAX.
(A d-c)
|
VOLTAGE CHANNEL
GV (V/V)
|
CURRENT CHANNEL
GI (A/V)
|
VOLTAGE MODE
|
CURRENT MODE
|
|
1000 WATT
|
| BOP 20-50GL |
0 to ±20 |
0 to ±50 |
2.0 |
5.0 |
0.02% |
0.01% |
| BOP 36-28GL |
0 to ±36 |
0 to ±28 |
3.6 |
2.8 |
0.02% |
0.01% |
| BOP 50-20GL |
0 to ±50 |
0 to ±20 |
5.0 |
2.0 |
0.02% |
0.01% |
NOTE: When connecting active loads, the steady-state voltage of the active load must not exceed the maximum voltage rating of the BOP. Otherwise the overvoltage protection will shut down the power supply.