   BOP 1 KILOWATT MODEL TABLE
MODEL d-c OUTPUT RANGE CLOSED LOOP GAIN OUTPUT IMPEDANCE
VOLTAGE
(V d-c)
CURRENT
(A d-c)
VOLTAGE
CHANNEL
GV (V/V)
CURRENT
CHANNEL
GI (A/V)
VOLTAGE MODE CURRENT MODE
SERIES R
(mΩ)
SERIES L
(µH)
SHUNT R
(Ω)
SHUNT C
(µF)
1000 WATT
BOP 6-125MG 0 to ±6 0 to ±125 0.6 12.5 0.05 1.5 24 1150
BOP 10-75MG 0 to ±10 0 to ±75 1.0 7.5 0.13 2.0 67 976
BOP 20-50MG 0 to ±20 0 to ±50 2.0 5.0 0.40 8.3 200 371
BOP 25-40MG 0 to ±25 0 to ±40 2.5 4.0 0.63 15.8 313 165
BOP 36-28MG 0 to ±36 0 to ±28 3.6 2.8 1.30 25 640 103
BOP 50-20MG 0 to ±50 0 to ±20 5.0 2.0 2.50 50 1250 55
BOP 72-14MG 0 to ±72 0 to ±14 7.2 1.4 5.14 104 2570 33
BOP 100-10MG 0 to ±100 0 to ±10 10.0 1.0 10.0 163 5000 16
NOTE: When connecting active loads, the steady-state voltage of the active load must not exceed the maximum voltage rating of the BOP. Otherwise the overvoltage protection will shut down the power supply.

   BOP 1 KILOWATT SERIES GL MODEL TABLE
MODEL d-c OUTPUT RANGE CLOSED LOOP GAIN RIPPLE AND NOISE
EO MAX.
(V d-c)
IO MAX.
(A d-c)
VOLTAGE
CHANNEL
GV (V/V)
CURRENT
CHANNEL
GI (A/V)
VOLTAGE MODE CURRENT MODE
1000 WATT
BOP 20-50GL 0 to ±20 0 to ±50 2.0 5.0 0.02% 0.01%
BOP 36-28GL 0 to ±36 0 to ±28 3.6 2.8 0.02% 0.01%
BOP 50-20GL 0 to ±50 0 to ±20 5.0 2.0 0.02% 0.01%
NOTE: When connecting active loads, the steady-state voltage of the active load must not exceed the maximum voltage rating of the BOP. Otherwise the overvoltage protection will shut down the power supply.

For other Volt-Ampere combinations, please consult factory.
PREVIOUS TOP NEXT

ProductsSupportLiteratureContact UsCareersAbout

KEPCO, INC. • 131-38 SANFORD AVENUE • FLUSHING, NY. 11355 U.S.A.
TEL (718) 461-7000 • FAX (718) 767-1102
www.kepcopower.com • email: hq@kepcopower.com