MODEL NUMBER(1)(2)
OPERATING LIMITS OVERLOAD PROTECTION MINIMUM ON
RESISTANCE
ALL MODES
(Ohms)
INPUT
IMPEDANCE
(Ohms)
RATED
POWER
(Watts)
RATED
VOLTAGE
(Volts)
RATED CURRENT
ALL MODES
(Amps)
POWER(3)
(Watts)
VOLTAGE(4)
(Volts)
CURRENT(5)
(Amps)
1000 WATT MODELS AND 1000 WATT DUAL CHANNEL MODELS(6)
EL 1K-50-100(6) 1000 50 100 1050 52.5 105 0.008 161K
EL 1K-200-100(6) 1000 200 100 1050 210 105 0.014 161K
EL 1K-400-70(6) 1000 400 70 1050 420 73.5 0.046 161K
EL 1K-600-30(6) 1000 600 30 1050 630 31.5 0.017 161K
2000 WATT MODELS AND 2000 WATT DUAL CHANNEL MODELS(6)
EL 2K-50-200(6) 2000 50 200 2100 52.5 210 0.004 80K
EL 2K-200-200(6) 2000 200 200 2100 210 210 0.007 80K
EL 2K-400-140(6) 2000 400 140 2100 420 147 0.023 80K
EL 2K-600-60(6) 2000 600 60 2100 630 63 0.083 80K
3000 WATT MODELS>
EL 3K-50-300 3000 50 300 3150 52.5 315 0.005 54K
EL 3K-200-300 3000 200 300 3150 210 315 0.005 54K
EL 3K-400-210 3000 400 210 3150 420 220.5 0.015 54K
EL 3K-600-90 3000 600 90 3150 630 94.5 0.056 54K
4000 WATT MODELS
EL 4K-50-500 4000 50 500 525 52.5 525 0.002 38K
EL 4K-200-500 4000 200 500 2100 210 525 0.003 38K
EL 4K-400-350 4000 400 350 4200 420 367.5 0.009 38K
EL 4K-600-150 4000 600 150 4200 630 157.5 0.333 38K
5000 WATT MODELS
EL 5K-50-600 5000 50 600 5250 52.5 630 0.002 26K
EL 5K-200-600 5000 200 600 5250 210 630 0.002 26K
EL 5K-400-420 5000 400 420 5250 420 441 0.008 26K
EL 5K-600-200 5000 600 200 5250 630 210 0.028 26K

(1) For GPIB interface, add suffix "G" to the model number. The GPIB interface is in addition to the standard RS 232 and USB interfaces, except for dual channel models the GPIB interface replaces the standard RS 232 and USB interfaces.
(2) For Ethernet interface (in addition to the standard RS 232 and USB interfaces), add suffix "E" to the model number.
(3) Maximum operating power and/or current may be reduced if operating conditions (ambient temperature, available air flow, etc.) cause internal load temperature to exceed safe operating conditions for FETs (TEMP FAULT).
(4) Maximum operating power and/or current may be reduced when ambient temperature exceeds 35°C, depending on air flow, duty cycle of load operation and other situational-specific conditions.
(5) Each FET is individually fused. Blown fuses are reported in unit status.
(6) For dual channel models (these models include two completely independent loads in a single chassis) add suffix "D" to the model number. Specifications listed are per channel for dual channel models.