   HSF-PFC MODEL TABLE: 300W
MODEL OUTPUT
VOLTS
(V d-c)
ADJUSTMENT RANGE(1)(2)
(V d-c)
OVP
SETTING(4)
(V d-c)
OUTPUT
CURRENT(5)
(A d-c)
0-40°C
OVERCURRENT
SETTING(6)
(A d-c)
RIPPLE/
NOISE(7)
(mV p-p)
External Resistance
or Voltage
Front Panel
Trimpot
Minimum
Adjustment(3)
HSF 5-60 5 0 - 5.5(3) 1.8 - 5.5 1.8 5.7 - 7.0 60 63 - 78 80/120
HSF 5-60M 5 0 - 5.5 0 - 5.5 0 5.7 - 7.0 60 63 - 78 80/120
HSF 12-27 12 0 - 13.8(3) 5.5 - 13.8 5.5 14.3 - 16.8 27 28.4 - 35.1 120/150
HSF 12-27M 12 0 - 13.8(3) 5.5 - 13.8 5.5 14.3 - 16.8 27 28.4 - 35.1 120/150
HSF 12-27MZ 12 0 - 13.8 0 - 13.8 0 14.3 - 16.8 27 28.4 - 35.1 120/150
HSF 15-22 15 0 - 17.4(3) 6.5 - 17.4 6.5 18.0 - 21.0 22 23.1 - 28.6 120/150
HSF 15-22M 15 0 - 17.4(3) 7 - 17.4 7 18.0 - 24.0 22 23.1 - 28.6 120/150
HSF 15-22MZ 15 0 - 17.4 0 - 17.4 0 18.0 - 24.0 22 23.1 - 28.6 120/150
HSF 24-14 24 0 - 28.2(3) 6.5 - 28.2 6.5 29.3 - 33.6 14 14.7 - 18.2 150/200
HSF 24-14M 24 0 - 28.2(3) 7 - 28.2 7 29.3 - 33.6 14 14.7 - 18.2 150/200
HSF 24-14MZ 24 0 - 28.2 0 - 28.2 0 29.3 - 33.6 14 14.7 - 18.2 150/200
HSF 28-12 28 0 - 33(3) 6.5 - 33 6.5 34.2 - 39.2 12 12.6 - 15.6 150/200
HSF 28-12M 28 0 - 33(3) 7 - 33 7 34.2 - 39.2 12 12.6 - 15.6 150/200
HSF 28-12MZ 28 0 - 33 0 - 33 0 34.2 - 39.2 12 12.6 - 15.6 150/200
HSF 48-7 48 0 - 52.2(3) 6.5 - 52.2 6.5 54.5 - 59.8 7 7.4 - 9.1 200/200
HSF 48-7M 48 0 - 52.2(3) 7 - 52.2 7 54.5 - 59.8 7 7.4 - 9.1 200/200
HSF 48-7MZ 48 0 - 52.2 0 - 52.2 0 54.5 - 59.8 7 7.4 - 9.1 200/200

(1) Using trimpot to attain voltages outside the specified adjustment range may trigger undervoltage or overvoltage faults.
(2) 0V is approximate (logic 0: 0.0 - 0.4V d-c).
(3) Observe minimum for proper functioning of alarm relay, optional meter and LED.
(4) When undervoltage or overvoltage is detected, output is shut OFF. Recovery is either by opening, then reconnecting, short across ±RC terminals (no delay), or by removing, and after approximately 40 seconds, reapplying a-c input power.
(5) See Power vs. Temperature for power derating.
(6) Square type. If overcurrent condition continues betond 30 seconds, the output is shut OFF. Recovery is the same as for undervoltage or overvoltage fault; see Note (4) above.
(7) Ripple and Noise specifications are 1.5 times indicated values for temperature range of -10°C to 0°C. Ripple and noise levels above are satisfied when conditions are 0 to 100% load, 0 to 40°C (see Power vs. Temperature for power derating between 40°C and 55°C) and bandwidth ≤ 100 MHz.