(1) Using trimpot to attain voltages outside the specified adjustment range may trigger undervoltage or overvoltage faults.
(2) 0V is approximate (logic 0: 0.0 - 0.4V d-c).
(3) Observe minimum for proper functioning of alarm relay, optional meter and LED. For W option, LED functions down to 0V.
(4) When undervoltage or overvoltage is detected, output is shut OFF. Recovery is either by opening, then reconnecting, short across ±RC terminals (no delay), or by removing, and after approximately 40 seconds, reapplying a-c input power.
(5) See Power vs. Temperature for power derating.
(6) Square type. If overcurrent condition continues betond 30 seconds, the output is shut OFF. Recovery is the same as for undervoltage or overvoltage fault; see Note (4) above.
(7) Ripple and Noise specifications are 1.5 times indicated values for temperature range of -10°C to 0°C. Ripple and noise levels above are satisfied when conditions are 0 to 100% load, 0 to 55°C (see Power vs. Temperature for power derating between 40°C and 55°C) and bandwidth ≤ 100 MHz.
|