   RKW PROGREAMMABLE MODEL TABLE
MODEL OUTPUT
VOLTAGE
Volts
ADJUSTMENT
RANGE
Volts
OVP
SETTING(1)
Volts
OUTPUT
CURRENT
Amps
-10 to +50°C
CURRENT
LIMIT(2)
Amps
SHORT
CIRCUIT
CURRENT
Amps
SWITCHING
RIPPLE
mV p-p
NOISE(3)
mV p-p
EFFICIENCY (%)
TYPICAL
100V a-c 200V a-c
30 WATT MODELS
RKW 3.3-7K 3.3 2.85 - 4.0 4.2 - 5.2 7.0 7.9 - 80 120 75 76
RKW 5-6K 5 4.0 - 5.8 6.0 - 6.9 6.0 6.3 - 80 120 77 78
RKW 12-2.5K 12 9.6 - 13.2 13.7 - 15.7 2.5 2.6 - 100 150 81 82
RKW 15-2K 15 12 - 16.5 17.0 - 19.0 2.0 2.1 - 100 150 81 83
RKW 24-1.3K 24 19.2 - 26.4 27.0 - 30.5 1.3 [2.0](4) 2.1 - 100 150 84 85
RKW 48-0.65K 48 38.4 - 52.8 55.0 - 60.0 0.65 0.68 - 130 200 84 85
50 WATT MODELS
RKW 3.3-12K 3.3 2.85 - 4.0 4.2 - 5.2 12.5 13.1 16 80 120 71 73
RKW 5-10K 5 4.0 - 5.8 6.0 - 6.9 10 10.5 12.6 80 120 75 78
RKW 12-4.3K 12 9.6 - 13.2 13.7 - 15.7 4.3 4.5 5.6 100 150 78 80
RKW 15-3.5K 15 12 - 16.5 17.0 - 19.0 3.5 3.6 5.4 100 150 78 80
RKW 24-2.2K(5) 24 19.2 - 26.4 27.0 - 30.5 2.2 [3.2](4) 3.3 6.2 100 150 79 82
RKW 48-1.1K 48 38.4 - 52.8 55.0 - 60.0 1.1 1.15 2.4 130 200 80 83
100 WATT MODELS
RKW 3.3-25K 3.3 2.85 - 4.0 4.2 - 5.2 25 26.25 37.5 80 120 74 77
RKW 5-20K 5 4.0 - 5.8 6.0 - 6.9 20 21.0 27.5 80 120 77 82
RKW 12-8.5K 12 9.6 - 13.2 13.7 - 15.7 8.5 8.92 11.5 100 150 80 84
RKW 15-7K 15 12 - 16.5 17.0 - 19.0 7 7.35 10 100 150 80 84
RKW 24-4.5K(5) 24 19.2 - 26.4 27.0 - 30.5 4.5 [6.5](4) 6.82 10 100 150 81 85
RKW 28-3.8K 28 22.4 - 30.8 32.0 - 35.0 3.8 3.99 7.5 100 150 81 85
RKW 48-2.1K 48 38.4 - 52.8 55.0 - 60.0 2.1 2.2 4.5 130 200 83 86
150 WATT MODELS
RKW 3.3-35K 3.3 2.85 - 4.0 4.2 - 5.2 35 36.75 45 80 120 73 77
RKW 5-30K 5 4.0 - 5.8 6.0 - 6.9 30 31.5 37 80 120 77 82
RKW 12-13K 12 9.6 - 13.2 13.7 - 15.7 13 13.65 18 100 150 80 84
RKW 15-10K 15 12 - 16.5 17.0 - 19.0 10 10.5 14 100 150 80 84
RKW 24-6.5K(5) 24 19.2 - 26.4 27.0 - 30.5 6.5 [10](4) 10.5 13 100 150 82 86
RKW 28-5.5K 28 22.4 - 30.8 32.0 - 35.0 5.5 5.78 9 100 150 82 86
RKW 48-3.3K 48 38.4 - 52.8 55.0 - 60.0 3.3 3.46 8.5 130 200 84 88

(1) An overvoltage shuts down the output. Recover by recycling a-c input.
(2) The current limit is rectangular. The 30W models have a "Winker" circuit. After the overload is removed, output is automatically restored.
(3) Bandwidth 100MHz. Ripple and noise will be approximately 1.5 times these values in the operating temperature range -10 to 0°C.
The ripple and noise values tabulated are valid when the output is derated as shown in Ratings vs Temperature. from 50 to 65°C.
(4) [ ] = Peak current (useful for motor start applications).
(5) These models include thermal protection: if overtemperature detected, output voltage is cut off. For 100W and 150W models, output voltage returns automatically after sufficient cooling; for 50W models, recover by cycling a-c input after sufficient cooling.