RKW PROGRAMMABLE MODEL TABLE
|
|
MODEL
|
OUTPUT VOLTAGE Volts
|
ADJUSTMENT RANGE Volts
|
OVP SETTING(1) Volts
|
OUTPUT CURRENT(2) Amps -10 to +50°C
|
CURRENT LIMIT(3) Amps
|
SHORT CIRCUIT CURRENT Amps
|
SWITCHING RIPPLE mV p-p
|
NOISE(4) mV p-p
|
EFFICIENCY (%) TYPICAL
|
|
100V a-c
|
200V a-c
|
|
300 WATT MODELS
|
| RKW 3.3-70K |
3.3 |
1.8 - 3.6 |
4.0 - 4.6 |
70 |
73.5 - 91 |
90 |
80 |
120 |
68 |
72 |
| RKW 5-60K |
5 |
3.5 - 6.0 |
6.2 - 7.0 |
60 |
63.0 - 78.0 |
82 |
80 |
120 |
74 |
78 |
| RKW 12-27K |
12 |
7.2 - 14.4 |
14.8 - 16.8 |
27 |
28.4 - 35.1 |
35 |
120 |
150 |
76 |
80 |
| RKW 15-22K |
15 |
10.5 - 18.0 |
18.6 - 21.0 |
22 |
23.1 - 28.6 |
29 |
120 |
150 |
77 |
81 |
RKW 24-14K |
24 |
16.8 - 28.8 |
29.8 - 33.6 |
14 |
14.7 - 18.2 |
20 |
150 |
200 |
80 |
84 |
RKW 28-12K |
28 |
19.6 - 33.6 |
34.7 - 39.2 |
12 |
12.6 - 15.6 |
17 |
150 |
200 |
80 |
84 |
RKW 48-7K |
48 |
33.6 - 52.8 |
55.0 - 59.9 |
7 |
7.4 - 9.1 |
11 |
200 |
300 |
81 |
85 |
|
600 WATT MODELS
|
| RKW 3.3-150K |
3.3 |
1.8 - 3.6 |
4.0 - 4.6 |
150 |
156 - 186 |
180 |
80 |
120 |
74 |
78 |
| RKW 5-120K |
5 |
3.5 - 6.0 |
6.2 - 7.0 |
120 |
126 - 156 |
160 |
80 |
120 |
76 |
81 |
| RKW 12-53K |
12 |
7.2 - 14.4 |
14.8 - 16.8 |
53 |
55.6 - 68.9 |
65 |
150 |
200 |
80 |
84 |
| RKW 15-43K |
15 |
10.5 - 18.0 |
18.6 - 21.0 |
43 |
45.1 - 55.9 |
55 |
150 |
200 |
81 |
85 |
RKW 24-27K |
24 |
16.8 - 28.8 |
29.8 - 33.6 |
27 |
28.3 - 35.1 |
35 |
200 |
300 |
82 |
86 |
RKW 28-23K |
28 |
19.6 - 33.6 |
34.7 - 39.2 |
23 |
24.1 - 29.8 |
29 |
200 |
300 |
82 |
86 |
RKW 48-13K |
48 |
33.6 - 52.8 |
55.0 - 59.9 |
13 |
13.7 - 16.9 |
19 |
300 |
400 |
84 |
87 |
|
1500 WATT MODELS
|
| RKW 3.3-375K |
3.3 |
1.8 - 3.6 |
4.0 - 4.6 |
375 |
390 - 430 |
430 |
100 |
200 |
73 |
77 |
| RKW 5-300K |
5 |
3.5 - 6.0 |
6.2 - 7.0 |
300 |
315 - 350 |
350 |
100 |
200 |
77 |
82 |
| RKW 12-125K |
12 |
7.2 - 14.4 |
14.8 - 16.8 |
125 |
130 - 140 |
152 |
150 |
200 |
80 |
84 |
| RKW 15-100K |
15 |
10.5 - 18.0 |
18.6 - 21.0 |
100 |
105 - 115 |
135 |
150 |
200 |
82 |
86 |
RKW 24-65K |
24 |
16.8 - 28.8 |
29.8 - 33.6 |
65 |
68 - 72 |
80 |
200 |
300 |
82 |
86 |
RKW 28-55K |
28 |
19.6 - 33.6 |
34.7 - 39.2 |
55 |
57.7 - 63.2 |
70 |
200 |
300 |
82 |
86 |
RKW 48-32K |
48 |
33.6 - 52.8 |
55.0 - 59.9 |
32 |
33.6 - 36.8 |
45 |
300 |
400 |
84 |
88 |
|
(1) An overvoltage shuts down the output. Recover by resetting the RC terminals. The overvoltage setting tracks the REF voltage.
(2) See Ratings vs Temperature.
(3) The current limit is rectangular. If overcurrent persists for more than 30 Seconds, the output shuts down. Reset by resetting the RC terminals.
(4) Bandwidth 100MHz. Ripple and noise will be approximately 1.5 times the values in the operating temperature range -10 to 0°C. The ripple and noise values tabulated are valid when the output is derated as shown in Ratings vs Temperature. from -10 to 0°C.
|
|