   BOP 100W, 200W, 400W MODEL TABLE
MODEL (1) (2) d-c Output Range Closed Loop Gain Output Impedance
EO max IO max Voltage
Channel
GV
(V/V)
Current
Channel
GA
(A/V)
Series R Series L (3) Shunt R Shunt C (4)
100 WATT MODELS
BOP 20-5M ±20V ±5A 2.0 0.5 80µΩ 20µH 40kΩ 0.05µF
BOP 50-2M ±50V ±2A 5.0 0.2 0.5mΩ 100µH 50kΩ 0.05µF
BOP 100-1M ±100V ±1A 10.0 0.1 2.0mΩ 200µH 100kΩ 0.05µF
200 WATT MODELS
BOP 20-10M ±20V ±10A 2.0 1.0 40µΩ 40µH 20kΩ 0.05µF
BOP 36-6M ±36V ±6A 3.6 0.6 120µΩ 20µH 36kΩ 0.03µF
BOP 50-4M ±50V ±4A 5.0 0.4 0.25mΩ 50µH 50kΩ 0.02µF
BOP 100-2M ±100V ±2A 10.0 0.2 1.0mΩ 60µH 100kΩ 0.03µF
BOP 200-1M (5) ±200V ±1A 20.0 0.1 4.0mΩ 1.2mH 200kΩ 0.03µF
400 WATT MODELS
BOP 20-20M ±20V ±20A 2.0 2.0 20µΩ 10µH 20kΩ 0.5µF
BOP 36-12M ±36V ±12A 3.6 1.2 60µΩ 50µH 36kΩ 0.4µF
BOP 50-8M ±50V ±8A 5.0 0.8 125µΩ 100µH 50kΩ 0.15µF
BOP 72-6M ±72V ±6A 7.2 0.6 240µΩ 200µH 72kΩ 0.1µF
BOP 100-4M ±100V ±4A 10.0 0.4 500µΩ 200µH 100kΩ 0.1µF

(1) For factory installed digital interfaces add appropriate suffix.
(2) To specify digital display, substitute the suffix letter “D” for the suffix letter “M.”
(3) For determining dynamic impedance in voltage mode.
(4) For determining dynamic impedance in current mode.
(5) Same size as 400W models.