   BOP 2 TO 6 KILOWATT SERIES MODEL TABLE
VOLTAGE SYSTEM POWER
2KW 3KW 4KW 5KW 6KW
6V 250A 375A 500A 625A 750A
10V 200A 300A 400A 500A 600A
20V 100A 150A 200A 250A 300A
36V 56A 84A 112A 140A 168A
50V 40A 60A 80A 100A 120A
72V 28A 42A 56A 70A 84A
100V 20A 30A 40A 50A 60A
200V 10A N/A 20A N/A 30A
  BOP 2KW Photo BOP 3KW Photo BOP 4KW Photo BOP 5KW Photo BOP 6KW Photo
NOTE: Model numbers are constructed as follows: BOP V-AX where
V = Listed Voltage
A = Listed Current
X = Suffix defining digital interface and front panel options:
    M = Models with M suffix include front panel display and keypad.
    G = Models with G suffix include built-in standard GPIB and RS 232 digital interfaces.
    E = Models with E suffix include built-in standard LXI Ethernet (LAN) and RS 232 digital interfaces.
For example, a model BOP 20-150MG defines a 3kW unit, 0 to ±20V, 0 to ±150A, with GPIB and RS 232 digital interfaces.
A model BOP 200-30ME defines a 6kW unit, 0 to ±200V, 0 to ±30A, with LXI Ethernet (LAN) and RS 232 digital interfaces.

   BOP 2 TO 6 KILOWATT SERIES
   MAGNET POWER SUPPLY MODEL TABLE
MODEL (1) d-c OUTPUT RANGE (2) PICTURE
EO MAX. (3)
(V d-c)
IO MAX.
(A d-c)
2 kW
BOP 10-200GL or EL 0 to ±10 0 to ±200 BOP 2KW Photo
BOP 20-100GL or EL 0 to ±20 0 to ±100
BOP 36-56GL or EL 0 to ±36 0 to ±56
BOP 50-40GL or EL 0 to ±50 0 to ±40
3 kW
BOP 10-300GL or EL 0 to ±10 0 to ±300 BOP 3KW Photo
BOP 20-150GL or EL 0 to ±20 0 to ±150
BOP 36-84GL or EL 0 to ±36 0 to ±84
BOP 50-60GL or EL 0 to ±50 0 to ±60
4 kW
BOP 10-400GL or EL 0 to ±10 0 to ±400 BOP 4KW Photo
BOP 20-200GL or EL 0 to ±20 0 to ±200
BOP 36-112GL or EL 0 to ±36 0 to ±112
BOP 50-80GL or EL 0 to ±50 0 to ±80
5 kW
BOP 10-500GL or EL 0 to ±10 0 to ±500 BOP 5KW Photo
BOP 20-250GL or EL 0 to ±20 0 to ±250
BOP 36-140GL or EL 0 to ±36 0 to ±140
BOP 50-100GL or EL 0 to ±50 0 to ±100
6 kW
BOP 10-600GL or EL 0 to ±10 0 to ±600 BOP 6KW Photo
BOP 20-300GL or EL 0 to ±20 0 to ±300
BOP 36-168GL or EL 0 to ±36 0 to ±168
BOP 50-120GL or EL 0 to ±50 0 to ±120
(1) Models with GL suffix include built-in standard GPIB and RS 232 digital interfaces.
Models with EL suffix include built-in standard LXI Ethernet (LAN) and RS 232 digital interfaces.
(2) For other Volt-Ampere combinations, please consult factory.
(3) When connecting active loads, the steady-state voltage of the active load must not exceed the maximum voltage rating of the BOP. Otherwise the overvoltage protection will shut down the power supply.