Follow @kepco_careers
Advanced Search
Kepco Power Solutions
718-461-7000
   BOP 100W, 200W, 400W MODEL TABLE
MODEL (1) (2) d-c Output Range Closed Loop Gain Output Impedance
EO max IO max Voltage
Channel
GV
(V/V)
Current
Channel
GA
(A/V)
Series R Series L (3) Shunt R Shunt C (4)
100 WATT MODELS
BOP 5-20D (5) 0 to 5V 0 to 20A 0.5 2.0 10Ω 4H 5kΩ 10F
BOP 20-5D 0 to 20V 0 to 5A 2.0 0.5 80Ω 20H 40kΩ 0.05F
BOP 50-2D 0 to 50V 0 to 2A 5.0 0.2 0.5mΩ 100H 50kΩ 0.05F
BOP 100-1D 0 to 100V 0 to 1A 10.0 0.1 2.0mΩ 200H 100kΩ 0.05F
200 WATT MODELS
BOP 5-30D (5) 0 to 5V 0 to 30A 0.5 3.0 10Ω 4H 5kΩ 15F
BOP 20-10D 0 to 20V 0 to 10A 2.0 1.0 40Ω 40H 20kΩ 0.05F
BOP 36-6D 0 to 36V 0 to 6A 3.6 0.6 120Ω 20H 36kΩ 0.03F
BOP 50-4D 0 to 50V 0 to 4A 5.0 0.4 0.25mΩ 50H 50kΩ 0.02F
BOP 72-3D 0 to 72V 0 to 3A 7.2 0.3 0.48mΩ 60H 72kΩ 0.05F
BOP 100-2D 0 to 100V 0 to 2A 10.0 0.2 1.0mΩ 60H 100kΩ 0.03F
BOP 200-1D (5) 0 to 200V 0 to 1A 20.0 0.1 4.0mΩ 1.2mH 200kΩ 0.03F
200 WATT DUAL CHANNEL MODELS (100 WATTS PER CHANNEL) (6)
BOP 2X5-20D 0 to 5V 0 to 20A 0.5 2.0 10Ω 4H 5kΩ 0.3F
BOP 2X20-5D 0 to 20V 0 to 5A 2.0 0.5 80Ω 20H 40kΩ 0.05F
BOP 2X50-2D 0 to 50V 0 to 2A 5.0 0.2 0.5mΩ 100H 50kΩ 0.05F
BOP 2X100-1D 0 to 100V 0 to 1A 10.0 0.1 2.0mΩ 200H 100kΩ 0.05F
400 WATT MODELS
BOP 20-20D 0 to 20V 0 to 20A 2.0 2.0 20Ω 10H 20kΩ 0.5F
BOP 36-12D 0 to 36V 0 to 12A 3.6 1.2 60Ω 50H 36kΩ 0.4F
BOP 50-8D 0 to 50V 0 to 8A 5.0 0.8 125Ω 100H 50kΩ 0.15F
BOP 72-6D 0 to 72V 0 to 6A 7.2 0.6 240Ω 200H 72kΩ 0.1F
BOP 100-4D 0 to 100V 0 to 4A 10.0 0.4 500Ω 200H 100kΩ 0.1F
400 WATT DUAL CHANNEL MODELS (200 WATTS PER CHANNEL) (6)
BOP 2X20-10D 0 to 20V 0 to 10A 2.0 1.0 40Ω 50H 20kΩ 0.1F
BOP 2X36-6D 0 to 36V 0 to 6A 3.6 0.6 120Ω 50H 36kΩ 0.1F
BOP 2X50-4D 0 to 50V 0 to 4A 5.0 0.4 0.25mΩ 100H 50kΩ 0.05F
BOP 2X72-3D 0 to 72V 0 to 3A 7.2 0.3 0.48mΩ 200H 72kΩ 0.05F
BOP 2X100-2D 0 to 100V 0 to 2A 10.0 0.2 1.0mΩ 200H 100kΩ 0.05F
(1) For factory installed digital interfaces add -4886 for GPIB interface or -802E for Ethernet/LAN interface. For models optimized for heavy inductive loads add suffix "L" and for models optimized for heavy capacitive loads add suffix "C"
(2) Analog meters are no longer available, suffix "D" indicates digital meters.
NOTE: "D" and "M" BOP's are identical except for the meters and are fully interchangeable.
(3) For determining dynamic impedance in voltage mode.
(4) For determining dynamic impedance in current mode.
(5) Same size as 400W models.
(6) Specifications for dual channel models are for each channel. Channels are galvanically isolated from each other.

PREVIOUS TOP NEXT

ProductsSupportLiteratureContact UsCareersAbout

KEPCO, INC. • 131-38 SANFORD AVENUE • FLUSHING, NY. 11355 U.S.A.
TEL (718) 461-7000 • FAX (718) 767-1102
www.kepcopower.com • email: hq@kepcopower.com